Dimas FS 350 Návod k obsluze Strana 38

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 68
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 37
23
English
A reversible and removable cutting guide enables
45° to 90° cuts to be made.
This cutting guide is machined in such a way that
it can be fitted in several positions in addition to its
right angle position from to 45° to the left or to
the right.
Cutting method9
Straight cuts (SEE FIG 14)
570 mm : the stop (C) prevents fingers
being trapped between the table and the
frame (SEE FIG 15).
> 570 et 650 mm : retract the stop (C)
under the table to increase the stroke.
Depth of cut adjustment10
Maintenance (the motor must be stopped)
11
Store in a dry place, not accessible to
children.
Maintain the tools carefully.
!
Clean the machine regularly.
Drain the tank (22) frequently to remove cutting
residue, which otherwise could block the pump
and cause it to wear out prematurely. (SEE FIG
17)
.
Swill out the tanks (1) and (22) with water.
Carefully clean the contact faces for the table
rollers.
FAULT FINDING
In the event of faulty operation refer to the tables
below to find a solution.
CAUSES
The machine does not work
Not plugged in proper-
ly or cable damaged
No mains voltage
Switch defective,
motor cable damaged
Motor faulty (no
power, unpleasant
smell)
- Make sure that the
supply is correctly
plugged in (plug,
extension lead, etc)
- Check the supply
cable
- Test or have tested
by an electrician (cir-
cuit breaker, plug,
etc)
- Have tested by an
electrician or contact
the service depart-
ment
- Contact the service
department to have
the motor replaced
REMEDIES
CAUSES
REMEDIES
Difficult starting
Single phase motor
starting condenser
Three-phase supply
not correct (on 2
phases, motor cable
faulty)
- Replace the
condenser
- Have it checked by
an electrician or
contact the service
department
CAUSES
REMEDIES
The pump does not start
The mains lead is not
correctly connected or
is damaged
No voltage in pump
circuit or mains supply
circuit
- Check the mains
lead
- Check the pump cir-
cuit and mains sup-
ply circuit
REMEDIES
The pump does not pump water
CAUSES
An air bubble may
have formed inside the
pump body
The turbine is jammed
- Holding the pump of
the outlet pipe remove
it from the water and
reimmerse it
- Unscrew the filter
and, using a small
screwdriver, remove
all dirt from the ope-
rating area of the tur-
bine.
(SEE FIG. 16)
.
Slacken off handle (6).
Use lever (5) to adjust the cutting height.
Tighten handle (6).
Zobrazit stránku 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 67 68

Komentáře k této Příručce

Žádné komentáře